Our Laboratories
Biosafety Level 2 Laboratory
All laboratory bench work involving Biosafety Level 2 (BSL-2) biological agents must be carried out in the BSL-2 Laboratory housed with NMRS' Biosafety Level 2 Facility. This laboratory has dedicated biological safety cabinets and equipment for handling of potentially pathogenic samples.
Our Specialist Equipment
This page provides an overview of the NMRS' specialist laboratory equipment. Please refer to our Laboratory Managers for the full list of equipment in our laboratories.
Researchers interested in using aquarium equipment should reach out to Aquarium Managers.
Please note that fees may apply for some equipment. The detailed schedule of rates can be found in the NMRS Researcher Handbook.
Microscopy and Imaging Equipment
Confocal microscope
Confocal Laser Scanning Microscopy (CLSM) is an optical imaging technique that uses a focused laser beam to scan a specimen and a spatial pinhole to reject out-of-focus light, thereby improving image contrast and axial (depth) resolution. By acquiring a series of two-dimensional (2D) optical sections at different depths within the specimen, a three-dimensional (3D) image can be reconstructed for better visualization of structures.
Apotome.2 Inverted Microscope
The Apotome is a widefield fluorescence microscope which allows for the creation of optical sections of samples using optical sectioning structured illumination (OS-SIM). The presence of a movable diffraction grating and changing angles generates several raw images which are then reconstructed post-imaging to create a super-resolved image.
Compound Miscroscopes
Compound light microscopes are commonly used in laboratories to observe small specimens at magnifications ranging from 40× to 1000×. They use visible light and a combination of objective and eyepiece lenses to magnify specimens, allowing detailed examination of cellular structures, microorganisms, and thin tissue sections.
Analytical Equipment
S3e Cell Sorter
Cell sorter is used to sort single cells up to 99% purity based on the fluorescent markers using a novel automated sorting setup at droplet frequency of 37-43 kHz. This system is equipped with a sorting system that maintaining a constant stream velocity during runs (sorting are more gently and accurately at high speed).
Molecular and Cellular Biology Equipment
Qubit 3 Fluorometer
The Qubit 3 fluorometer help researchers quantify the amount of DNA, RNA or protein that their samples contain, allowing them to determine if they have sufficient quantity of desired product. It is a useful check before researchers proceed with next generation sequencing (NGS), PCR or western blotting.
MLR-352 Climate Chamber
These programmable climate chambers allow temperature settings between 0°C to 50°C, and lighting control between 0 to 20,000 lux. Illumination is provided from three sides and racks are adjustable with maximum loading up to 20 kg per shelf. Aeration can also be supplied via airlines drawn from the top of the chamber.
Binder KBW 240 Climate Chamber
Climatic chamber with temperature and three different levels (3000, 6000 & 9000 Lux) of illumination control. Lightning is provided from top-down configuration, achieving uniform illumination across the entire rack. This unit of chamber is equipped with two light cassettes and lighting intensity can be independently controlled for each rack. Aeration can also be supplied via airlines drawn from side port.
Miscellaneous Equipment
Histology Equipment
Histology is the study of biological tissues under a microscope. Producing the histological slides requires a series of processing through the use of three instruments – Thermo Scientific Shandon Citadel 2000 Tissue Processor, Leica RM2135 Rotary Microtome and the Shandon Histo-Center II.
Furnace
The Carbolite AAF1100 can be operated from 30-3000 °C. The high operating temperature allows for researchers to combust and burn away the organic matter of samples, leaving behind the ash. Different timer programmes can be set allowing researchers to control temperature, temperature ramp rate, program shut off.