Laboratories and Specialist Equipment

ZEISS Laser Confocal Microscope

Description

Confocal Laser Scanning Microscopy (CLSM) is an optical imaging technique that uses a focused laser beam to scan a specimen and a spatial pinhole to reject out-of-focus light, thereby improving image contrast and axial (depth) resolution. By acquiring a series of two-dimensional (2D) optical sections at different depths within the specimen, a three-dimensional (3D) image can be reconstructed for better visualization of structures

The laser source of this system is completed enclosed by an opaque barrier. Thus, the user of this system is exempted from obtaining the N3 license.

Technical specifications
Microscope Stand

 

Motorized Z-drive (smallest increment 10 nm)

TFT touchscreen monitor with flat fine drive knob and fine drive disk (with scale and changeable)

Motorized 6-position objective nosepiece for brightfield, darkfield, ACR and DIC

Motorized transmitted-light illumination, motorized light control

Binocular phototube (100:0/0:100) 15°/field of view 25 mm showing upright image, 2X eyepiece for eyeglass wearers PL 10x/field of view 25 mm

Transmitted light illumination Transmitted light with DIC set for LSM

LSM ESID (LED light source and transmitted detector)

Reflected light illumination

 

Reflected-light FL BD set manual for Imager with LSM

Solid-state light source Colibri 5, type RGB-UV

Filter set 90 HE LED for DAPI, FITC, TRITC and Cy5

Reflector module FL EC P&C

Reflector module bright field ACR P&C for reflected light

Scanning Stage

 

130 x 85 STEP with stepper motor (1 mm spindle pitch), including stepper controller SMC 2009, Joystick XY and mounting frame for slide 76x26 with frame size 160x116

Travel range 130 mm x 85 mm

Speed 25 mm/s

Resolution: 0.1 µm

Reproducibility: < 1 µm

Absolute accuracy: +/- 5 µm

Objectives

 

Objective EC Plan-Neofluar 1.25x/0.03

Objective Plan-Apochromat 10x/0.45 M27

Objective LD Plan-Neofluar 20x/0.4 Corr M27

Objective LD Plan-Neofluar 40x/0.6 Corr M27

Objective Plan-Apochromat 63x/1.4 Oil DIC M27

Objective Plan-Apochromat 100x/1.4 Oil DIC M27

DIC slider Plan-Apo 10x/0.45 II

DIC slider LD PN 20x/0.40 II

DIC slider LD PN 40x/0.60 II

DIC slider PA 63x/1.40 III

DIC slider Plan-Apochromat 100x/1.4 III

LSM800 Scan head LSM 900 Laser module LM URGB (D) with fiber-coupled, pigtailed and collimated lasers

Diode laser 405 nm, 5 mW, laser class 3B

Diode laser 488 nm, 10 mW, laser class 3B

Diode laser (SHG) 561 nm, 10 mW, laser class 3B

Diode laser 640 nm, 5 mW, laser class 3B

Directly modulated, dynamic range 10.000:1 effective

LSM 900 MA-PMT detection module

2-channel deflecting optics

OEM computer system and software Slim SuperMulti DVDRW

Real time controller imaging systems

ZEN 3.0 system hardware license key

ZEN module tiles & positions hardware license key

ZEN module deconvolution hardware license key

Offline workstation ZEN desk hardware license key
Accessories Crossline micrometer 10:100, d = 26 mm

Universal mounting frame for petri dish and slides

Dark incubation box Incubator XL S1 for Axio Imager Z1 LSM (D)

Docking station for TFT-display

Laser safety accessories

 

Light shielding cover

Laser safety lock modification (by SCS)

 

What kind of project is suitable for this equipment?
  • Users who wish to obtain high quality images or structures of specimens in their natural 3D state
  • Users who wish to observe and reconstruct in detail the habitus and dissected appendages, whole specimens and any dissected parts
  • For long-term digital records purposes. Photos taken by CLSM reduce the need of acquiring type specimens from museums for comparisons, which often damage type material in the midst of transfers and lab activity.

 

nrf logo